Power Quality Analysis
Power quality analysis is the foundation of effective electrical system improvement. Before any corrective action can be taken, the actual behaviour of the electrical system must be measured, recorded, and understood. Technical Solutions provides professional power quality analysis services using Class-A network analysers and structured engineering methodology. Measurement Technical Solutions deploys professional-grade power quality instruments […]
Power quality analysis is the foundation of effective electrical system improvement. Before any corrective action can be taken, the actual behaviour of the electrical system must be measured, recorded, and understood. Technical Solutions provides professional power quality analysis services using Class-A network analysers and structured engineering methodology.
Measurement
Technical Solutions deploys professional-grade power quality instruments at strategic points in the electrical network:
- IEC 61000-4-30 Class A analysers — the highest accuracy class for power quality measurement, ensuring legally defensible and technically reliable data
- Multi-point deployment — instruments installed simultaneously at multiple locations to capture system-wide behaviour
- Extended recording periods — typically 7 to 14 days of continuous recording to capture intermittent events and load cycle variations
- All electrical parameters — voltage, current, frequency, power, power factor, harmonics, flicker, unbalance, transients, and events
Analysis
Raw measurement data is analysed by our engineering team to identify:
- Harmonic distortion — total harmonic distortion (THD) levels and individual harmonic magnitudes, identifying polluting loads and affected circuits
- Voltage events — sags, swells, interruptions, and transients with timestamps, durations, and severity
- Power factor and reactive power — displacement and distortion power factor, identifying opportunities for correction
- Frequency stability — particularly relevant for generator-supplied or weak grid installations
- Phase unbalance — voltage and current unbalance that can cause motor overheating and equipment stress
- Flicker — rapid voltage fluctuations caused by intermittent loads such as arc furnaces or large motor starts
Event Capture
Power quality events — transients, sags, and disturbances — are often brief and unpredictable. Our instruments capture:
- Waveform recordings — detailed voltage and current waveforms during disturbance events
- RMS event recording — half-cycle RMS measurements for event characterisation
- Triggered captures — automatic recording when parameter thresholds are exceeded
- Time correlation — synchronised timestamps across multiple measurement points for cause-and-effect analysis
Reporting
Technical Solutions delivers comprehensive engineering reports that translate measurement data into actionable information:
- Executive summary — key findings, risk assessment, and recommended actions
- Detailed measurements — tabulated and graphed parameter values with standards comparison
- Event analysis — characterisation of captured disturbances with probable causes
- Compliance assessment — comparison against IEC 61000, IEEE 519, and relevant utility standards
- Recommendations — specific engineering measures to address identified issues, with estimated costs and benefits
- Supporting data — raw measurement files for client reference
Practical Problem Solving
Power quality analysis from Technical Solutions is not an academic exercise. Our reports are designed to lead directly to practical solutions:
- Harmonic sources are identified with specific corrective measures (active filters, passive filters, isolation transformers)
- Voltage issues are traced to root causes with recommended mitigation (stabilisers, tap changers, network reinforcement)
- Protection settings are reviewed against actual fault and load conditions
- Energy waste from poor power factor is quantified with correction equipment recommendations
Power Quality & Electrical Engineering Overview → | Harmonics & Reactive Power → | Discuss Your Project → | Contact Technical Solutions →
Comprehensive Execution
From feasibility studies through procurement, integration, and commissioning, we deliver end-to-end engineered solutions tailored to precise operational environments.
Related Information
Generator Synchronization
Facilities that operate multiple generators — or need to interface generators with the utility grid — require precise synchronisation systems. Technical Solutions designs, supplies, and commissions generator synchronisation solutions that ensure safe, reliable, and efficient parallel operation. Synchronizing Multiple Generators Automatic synchronisation control for paralleling two or more generators Voltage, frequency, and phase angle matching […]
Learn more
Grounding & Protection Studies
Effective earthing, protection coordination, and distribution system design are fundamental requirements for safe and reliable electrical installations. Technical Solutions provides engineering studies and implementation services that ensure these critical systems function correctly. Grounding and Earthing Earthing system design — electrode specification, conductor sizing, and system topology (TN, TT, IT) selection Earth resistance measurement — fall-of-potential […]
Learn more
Harmonics & Reactive Power
Harmonic distortion and reactive power are two of the most common — and most costly — power quality issues in modern electrical installations. Technical Solutions provides engineering analysis and corrective solutions for both. Harmonic Distortion Non-linear loads such as variable speed drives, UPS systems, rectifiers, and LED lighting inject harmonic currents into the electrical supply. […]
Learn moreReady to discuss your requirements?
Connect with our engineering team for a structured project assessment, scope discussion, or technical procurement conversation.