Switchgear, UPS, and critical distribution
LV/MV switchgear, motor control centres, UPS, and protection systems engineered to keep critical operations online — from oil & gas and data centres to municipal pumping.
Keep critical loads online
Our power and controls scope covers everything from incoming MV switchgear through main and sub-distribution to terminal panels. We integrate UPS, generators, automatic transfer schemes, and protection relays so that mission-critical loads — data centres, hospitals, control rooms, treatment plants — keep running when the grid does not.
Core components
- MV switchgear (air-insulated, IEC 62271-200) up to 36 kV
- LV switchgear (Form 4b, IEC 61439) up to 6300 A
- Intelligent motor control centres
- Numerical protection relays (IEC 61850)
- Oil and dry-type transformers
- Online double-conversion UPS systems
- Industrial DC battery systems (110/220 V DC)
- Automatic transfer switches and synchronizing panels
- Generators and synchronizing controls
- Power factor correction and harmonic filtering
Applications
- Oil & gas substations and control rooms
- Utility primary and secondary substations
- Water and wastewater pumping stations
- Industrial plants and MCC rooms
- Data centres and SCADA rooms
- Hospitals and emergency services
- Commercial buildings and campuses
Reliability targets
Topologies are selected against the criticality of the load — 2N for tier-3+ data centres and surgical suites, N+1 for control rooms and primary substations, single-stream with bypass for industrial plants. Protection coordination, arc-flash, and short-circuit studies accompany every detailed design.
Advantages
- Tier-1 type-tested assemblies
- Coordinated protection with documented studies
- Integrated SCADA and BMS interfaces
- Modular construction for future expansion
- Trained local field and service team
Key design considerations
- Load profile and growth
- Short-circuit and arc-flash levels
- Earthing strategy
- Selective protection coordination
- Harmonics and power quality
- Equipment derating for high ambient
- Spares and maintenance access
Our services
- Single-line and protection studies
- Switchgear and MCC specification
- Factory acceptance testing
- Site installation, cable termination, and energization
- UPS and battery sizing and installation
- Protection setting and coordination
- Operator and maintenance training
- Long-term service contracts
Plan your project
Tell us about your facility, your loads, and your timeline. Our engineers will respond within one business day.